19 February 2007
Although not noticeable live, in certain circumstances a flicker can be perceived on camera when using Color Blocks with High Definition or high speed cameras. This flicker can normally be resolved satisfactorily by camera adjustment, however Spectrum Manufacturing have developed a software modification to resolve this issue if camera adjustment is not possible. Only the following serial numbers are affected:
| Start | Stop | Start | Stop | Start | Stop |
| 505017249 | 505017290 | 505018781 | 505018801 | 306022345 | 306022384 |
| 505017334 | 505017335 | 505019203 | 306022388 | 306022395 | |
| 505017382 | 505017555 | 505019400 | 505019419 | 306022400 | 306022402 |
| 505017559 | 505017608 | 505019440 | 505019457 | 306022431 | 306022504 |
| 505017669 | 505017748 | 505019477 | 505019493 | 306022571 | 306022677 |
| 505017756 | 505017805 | 505019691 | 505019693 | 306022797 | 306022902 |
| 505017861 | 505017879 | 505019712 | 306023056 | 306023163 | |
| 505017881 | 505017960 | 505020119 | 505020123 | 306023166 | 306023185 |
| 505017982 | 505018010 | 505020699 | 505020876 | 306023190 | 306023191 |
| 505018244 | 505018331 | 505021124 | 505021181 | 306023295 | 306023394 |
| 505018336 | 505018347 | 505021211 | 505021306 | 306023421 | 306023529 |
| 505018349 | 505018388 | 505021501 | 505021635 | 306023604 | 306023613 |
| 505018391 | 505018436 | 505021693 | 505021769 | 306023687 | 306023721 |
| 505018440 | 505018509 | 505021850 | 505021948 | 306025139 | 306025141 |
| 505018522 | 505018579 | 505022077 | 505022078 | 306025665 | 306025670 |
| 505018610 | 505018619 | 505022085 | 505022097 | 306025697 | 306025704 |
| 505018721 | 505018727 | 505022294 | 505022343 | 306025768 | 306025769 |
The modification can be carried out free-of-charge at the A.C. Entertainment Technologies facility in High Wycombe UK or A.C. Lighting Inc facility in Toronto, Canada. All shipping costs are chargeable. Please contact the A.C. Entertainment Technologies technical sales departments for details.
Note: While all due care has been taken in the preparation of this document, Chroma-Q shall not be liable for any inaccuracies or omissions which may occur herein.